SPECIFICATIONS
POWER LED INDICATOR
MIC OUT (TO STUDIO)
MIC ON-AIR ARM
GPI STUDIO
Axia TCP link
Global TCP receive
DHD Global logic support
3 ways to switch the MIC ON-AIR SWITCH
Option 1: TCP link (Axia TCP, Global TCP receive or DHD global logic)
Option 2: 5VDC control voltage (10mA)
Option 3: Closed contact
12VDC POWER INPUT
DESCRIPTION
Suitable for signalling of on-air lamps for microphones. eg YELLOWTEC MIKA ON-AIR MIC ARM.
ON-AIR = red
OFF-AIR: white
The MOS-UNO-IP is unique in it’s kind. Not only does it support GPI, but also Axia’s TCP commands, global TCP link for external servers or DHD’s Ethernet global logic, making GPI hand soldering obsolete. The internal webserver allows full configuration of all needed settings.
STATUS LED INDICATOR
The LED will light up when the 12VDC power supply is present.
12VDC POWER INPUT
Ratings: 12VDC (9~18 volt) at 250mA. Polarity is not important
Power supply is included, options: 115V/USA - 230V/AUS - 230V/EUR - 230V/UK
MIC OUT (TO STUDIO)
Microphone output; connect to your equipment with standard MIC cable (XLR 3pin)
- PIN1: Ground (Shield)
- PIN2: Positive (Red)
- PIN3: Negative (Blue)
MIC ONAIR ARM
Connect to the MIC ON-AIR ARM with standard MIC cable (XLR 5pin)
- PIN1: Ground (Shield)
- PIN2: Positive (Red)
- PIN3: Negative (Blue)
- PIN4: LED (Yellow)
- PIN5: LED (Black)